Page 82 - Ingeniantes 621 interactivo
P. 82
Revista Ingeniantes 2019 Año 6 No. 2 Vol. 1
y susceptible de fabricarse en serie por alguna empre- [9] Meloni, G. N. (2016). Building a Microcontroller
sa nacional para beneficio de personas con DM2 con Based Potentiostat: A Inexpensive and Versatile Pla-
recursos económicos limitados y reducir, en una medi- tform for Teaching Electrochemistry and Instrumen-
da modesta, la dependencia tecnológica del extranjero tation. J. Chem. Educ. 2016, 93, 1320−1322.
que se tiene con respecto a estos instrumentos. [10] Punter Villagrasa, J., Colomer-Farrarons, J.
BIBLIOGRAFÍA and Miribel, P. Ll. (2013). Bioelectronics for Ampe-
[1] (2018). Diabetes. Consultado el 4 de noviembre rometric Biosensors, State of the Art in Biosensors
de 2018, Texas Hearth Institute, página web: https:// - General Aspects. En Toonika Rinken, IntechOpen.
www.texasheart.org/heart-health/heart-informa- DOI: 10.5772/52248. Disponible en: https://www.
tion-center/topics/diabetes-2/ intechopen.com/books/state-of-the-art-in-biosen-
[2] Moreno, L. (2001). Epidemiología y diabetes sors-general-aspects/bioelectronics-for-ampero-
[versión electrónica]. Revista de la Facultad de Me- metric-biosensors
dicina UNAM, 44(1), 35-37. [11] Britz, D. (1978). IR Elimination in Electrochemical
[3] (2016). Principales causas de mortalidad por re- Cells.. J. Electroanal. Chem., 88, 309—352.
sidencia habitual, grupos de edad y sexo del falle- [12] Souto, R. M. (1994). Electronic Configurations
cido. Consultado el 4 de noviembre de 2018, INEGI, in Potentiostats for the Correction of Ohmic Losses.
página web: http://www.inegi.org.mx/est/conteni- Electroanalysis, 6(7), 531-542.
dos/proyectos/registros/vitales/mortalidad/tabula- [13] N. Anju Latha, B. Rama Murthy, U. Sunitha.
dos/ConsultaMortalidad.asp (2012). Design and Development of a Microcontro-
[4] (2013). Se presenta el ‘perfil de glucosa ambu- ller Based System for the Measurement of Blood
latorio’, nuevo concepto en la monitorización de la Glucose. International Journal of Engineering Re-
glucosa. Consultado el 5 de noviembre de 2018, search and Applications (IJERA): Vol. 2, Issue 5,
página web: http://www.jano.es/noticia-se-presen- (pp.1440-1444).
ta-el-perfil-glucosa-20551 [14] Dalvi, N. (2013). Glucose Meter Reference De-
[5] Austin Anoop, N., Madhu Mohan, K. Guruvayu- sign (AN1560). Microchip Technology Inc. 2013.
rappan. (2014). Simulation of a multi-strip blood [15] Suárez, R. and Casillas, C. (2009). Implemen-
glucometer. TENCON-IEEE Region 10 Conference ting a Glucometer and Blood Pressure Monitor Me-
2014: DOI:10.1109/TENCON.2014.7022473. dical Devices. (AN4025). Freescale Semiconductor
[6] Shumit, S., Nayan, S., Avijit, H. (2014). Design & Document Number: Application Note Rev. 1, 4/2010.
Implementation of a Low Cost Blood Glucose Me- Freescale Semiconductor, Inc.
ter with High Accuracy. International Conference [16] Mule, S. S., Mujawar, T. H., Kasbe, M. S., Des-
on Electrical Engineering and Information & Com- hmukh, L. P. (2016). Microcontroller Based Blood
munication Technology (ICEEICT). DOI:10.1109/ Glucose Meter: Design and Development. Interna-
iceeict.2014.6919050 tional Journal of Engineering Sciences & Emerging
[7] Wen-Yaw Sun Tai-Ping Chung, A.C. Paglinawan, Technologies: Vol. 8 (5) (pp. 234-239).
Ying-hsiang Wang, T. Kuo. (2007). A 600 µW Rea- [17] Huante, J. y López, J. (2008). Diseño y cons-
dout Circuit with Potentiostat for Amperometric trucción de equipo para la monitorización continua
Chemical Sensors and Glucose Meter Applications. de glucosa con MSP. Consultado el 5 de noviembre
Conference on Electron Devices and Solid-State de 2018, Instituto Politécnico Nacional, página web:
Circuits. (pp. 1087-1090) https://tesis.ipn.mx/handle/123456789/23564
DOI:10.1109/edssc.2007.4450317
[8] Team 2: Bularzik, M., Price, D., Rivera, M. (n.d.) [18] Moreno, N. y Ordoñez, F. (2003). Biosensor no
Accessible Blood Glucose Monitor. University of invasivo para el monitoreo de la glucosa en sangre.
Connecticut. Biomedical Engineering Senior Design Consultado el 5 de noviembre de 2018, Instituto Po-
Team 2. Sponsored by the Rehabilitation Enginee- litécnico Nacional, página web: https://tesis.ipn.mx/
ring Research Center on Accessible Medical Ins- handle/123456789/18452
trumentation (RERC on AMI). Obtenido el 5 de no- [19] Estrada, M. (2015). Glucómetro con alerta de hi-
viembre de 2018, de la página electrónica: https:// poglucemia y almacenamiento de información para
www.yumpu.com/en/document/view/34317699/ personas mayores. Consultado el 5 de noviembre
accessible-blood-glucose-monitor-biomedical-en- de 2018, Universidad de las Américas Puebla, pá-
gineering-
78